Manufacturing Wastewater Treatment Case Studies

Ammunitions Manufacturing Wastewater Treatment
$160k Saved Per Year

An ammunition manufacturing facility was having problems removing copper and zinc from their 900 gpm wastewater system. The process used lime to raise the pH from 1.5 to 10, sodium carbamate for a metal precipitant, and an anionic flocculant to increase the flock size and get the solids to settle in the clarifier. Current chemical costs are estimated at $225,000/year with a significant amount of sludge addition from the lime, thereby adding to the operational costs due to the sludge being a hazardous waste.

Integrated Engineers, Inc. tested the wastewater and found that adding caustic to a pH of 10.0 and Floccin™ D worked as well as the current chemistry. The Floccin™ D dosage was 0.35 grams in 800 ml (280 ppm). The third sample shown below is with 160 ppm of IE-061. The test results are shown below:

Industrial Ammunition Manufacturer Wastewater Treatment Sample Testing

In addition, by switching from lime to caustic the reduction in solids generation would be a significant cost reduction. At peak flow the amount of lime required (17.3 lbs./1,000 gallons) generates 7,450 pounds of 100% dry solids. In a normally dry cake the solids are 30%, therefore they were generating nearly 25,000 lbs. of sludge per day that was hazardous and expensive to dispose of in a landfill. Based on a disposal cost of $35/ton, the cost reduction due to the lime addition to the sludge would be $450 per day ($160,000/year).

Follow the links at the left for more industrial wastewater treatment manufacturing case studies.

Download more manufacturing industry case studies here>>>

Get Started Right Away>>>Get Started

Call 1-877-965-1577
Toll Free

Wastewater Treatment Success Stories Home

Integrated Engineers Inc Logo

Featured Case Studies

Case Studies By Industry

More Featured Case Studies

Better Business Bureau Accreditation

Call 1-877-965-1577 Toll Free

Integrated Engineers Incorporated
40308 Greenwood Way
Oakhurst, CA 93644 USA
Country Code +1
(877) 965-1577 toll free
(559) 683-8284 phone
(559) 683-8913 fax

Email us:

sales@wecleanwater.com

Check Out Our Industrial Wastewater Treatment Environmental Expert Profile

*© 2011 Copyright Integrated Engineers , Inc., all Floccin™ products and equipment designed by Integrated Engineers, Inc., disclosed herein on this website are the exclusive properties of Integrated Engineers, Inc. and shall not be copied or reproduced in whole or in part without the express written consent of Integrated Engineers, Inc.... Click Here to Read about How Integrated has saved industry millions...You may find savings too! Find out now...

Call 1-877-965-1577

 

Bookmark and Share