Potato Flume Water 2010

Potato Processing Plant Wastewater Treatment

This is the wastewater sample that was received from a potato processing facility.

The facility utilizes water in a flume to transport potatoes. The resulting flume water has high levels of suspended solids. The flume water from the facility was tested with the Floccin™ K and it treated well at a dosage of 0.75g/1000 ml which equates to a dosage of 6.26 lbs/1,000 gallon.

A 1,000ml beaker filled with the water sample was used to conduct the treatability; the starting pH was recorded at 6.3. Floccin™ K was used for testing. 0.75 grams of Floccin™ K was added to the 1,000 ml beaker containing the wastewater.

Flocculation occurred around 30 seconds of mixing and after 3 minutes of mixing, the beaker was removed from the mixer and the solids were allowed to settle. The treated water had very low turbidity.

The results are shown in the photos below:

Potato Processor Flume Wastewater Sample Treatability Test

Left: Untreated Wastewater Sample Right: Treated

The water was tested with different dosages of Floccin™ in order to observe the clarity of the water at different dosages. The water was treated with 0.5 grams and flocculated well but the treated water was slightly cloudy. Treating with 1 gram of Floccin™ K produced results that were indistinguishable from the water treated with 0.75 grams.

The results are pictured below.

Floccin K .5 & .75 Grams Per 1000ml of Potato Flume Wastewater

Left: .5 Grams/1000ml Wastewater Right: .75 Grams/1000ml

Good flocculation was achieved with 0.5 grams Floccin™ K in a 1000ml beaker however the resulting treated water had higher turbidity than the water treated with higher dosages.

There was no perceivable improvement in water clarity for water treated at higher dosages than 0.75 gm/1000ml.

Potato Processor Wastewater Test .75 & 1 gram per 1000ml Wastewater

Left: .75 Grams/1000ml Wastewater Right: 1 Gram/1000ml Wastewater

Wastewater Lagoon

The water from Lagoon 1 was treated with Floccin™ K and it treated well with 0.5 grams of Floccin™ K in a 1,000 ml beaker. This equates to 4.17 lbs/1000 gallons. Flocculation began after about 30 second and after 3 minutes of mixing the solids were allowed to settle and the settling occurred quickly.

Potato Wastewater Lagoon 1 Wastewater Sample

Left: Untreated Lagoon 1 Sample Right: Treated

The water from Lagoon 2 was treated with Floccin™ K and it treated well with 0.5 grams of Floccin™ K in a 1000 ml beaker which equates to 4.17 lbs/1000 gallons. Flocculation began after about 30 second and after 3 minutes of mixing the solids were allowed to settle and the settling occurred quickly. The results are shown in the picture below.

Potato Wastewater Lagoon 2 Wastewater Sample

Left: Untreated Lagoon 2 Sample Right: Treated

Download pdf of this case study...

For more food processing industry case studies download here...

Get Started Now...Get Started

Call 1-877-965-1577
Toll Free

Wastewater Treatment Success Stories Home

Integrated Engineers Inc Logo

Featured Case Studies

Case Studies By Industry

More Featured Case Studies

Better Business Bureau Accreditation

Call 1-877-965-1577 Toll Free

Integrated Engineers Incorporated
40308 Greenwood Way
Oakhurst, CA 93644 USA
Country Code +1
(877) 965-1577 toll free
(559) 683-8284 phone
(559) 683-8913 fax

Email us:

sales@wecleanwater.com

Check Out Our Industrial Wastewater Treatment Environmental Expert Profile

*© 2011 Copyright Integrated Engineers , Inc., all Floccin™ products and equipment designed by Integrated Engineers, Inc., disclosed herein on this website are the exclusive properties of Integrated Engineers, Inc. and shall not be copied or reproduced in whole or in part without the express written consent of Integrated Engineers, Inc.... Click Here to Read about How Integrated has saved industry millions...You may find savings too! Find out now...

Call 1-877-965-1577

 

Bookmark and Share