Tortilla Producer Wastewater

Tortilla Producer Wastewater Case Study

TSS Drops from 1,883 ppm to 14 ppm

This facility manufactures corn tortillas using a solution of Lye to peel the skin from the corn and soften the corn.

The pH of the sample was received at 13.80 indicating a high basic solution.

To minimize operating costs, CO2 was used to drop the pH down to 8.0 instead of using the traditional acid.

The high pH water required about 5 minutes of sparging with the CO2 in order to drop the pH. Floccin™ 1105 was added at a dosage of 2 grams/1,000 ml and the water quality is shown below.

The wastewater required about 3 minutes of intense mixing to obtain this water clarity. The untreated suspended solids was measured at 1,833 ppm and the treated sample was at 14 ppm.

 

Tortilla Manufacturer Wastewater Case Study

 

Click to Download pdf of this Tortilla Producer Wastewater Study…

Download more industrial wastewater treatment case studies here…

Mexican Textile Dyeing Wastewater Case Study #2

Second Mexican Textile Dyeing Wastewater Case Study

Increase Capacity, Increase Compliance, Increase Profits *

This facility dyes material and this is a sample of their dye wastewater.

The pH was 7.27 and Floccin™ JP+ was used at a dosage of 0.5 grams/1,000 ml (4.17 lbs or 0.5 kg/ton of water).

The treated pH was 9.15.

The water was then filtered to simulate a settling or liquid/solids separation step.

The untreated suspended solids was measured at 285 ppm and the treated suspended solids were 25 ppm.

Mexican Textile Dyeing Wastewater Sample Test

Click to Download pdf of this Mexican Dyeing Wastewater Case Study #2…

Download more industrial wastewater treatment case studies here…

Mexican Textile Dyeing Wastewater #1

First Mexican Textile Dyeing Wastewater Case Study

Increase Capacity, Increase Compliance, Increase Profits *

This facility dyes material and this is a sample of their dye wastewater.

The pH was 9.73 and Floccin™ 909 was used at a dosage of 1 grams/1,000 ml (8.34 lbs or 1 kg/ton of water).

The treated pH was 9.3.

The water was then filtered to simulate a settling or liquid/solids separation step.

The untreated suspended solids was measured at 1,130 ppm and the treated suspended solids were 9 ppm.

Mexican Textile Dyeing Wastewater Sample Test

Click to Download pdf of this Mexican Dyeing Wastewater Case Study…

Download more industrial wastewater treatment case studies here…

Decorative Concrete Manufacturer

Floccin™ 909 excels in decorative concrete manufacturer wastewater jar test. The sample was high in solids including latex and coloring additives.

Click here to read the decorative concrete manufacturer wastewater case study and download a pdf…

Oil Water Separation

We’ve added a few new wastewater treatment equipment pages on oil water separation. These links are in the left sidebar of the equipment section as well:

Oil Water Separators

Wastewater Management

If your looking for wastewater management look no further. Integrated Engineers Inc has been providing industry with wastewater management solutions that improve efficiency, cut costs, increase capacity and increase ease of compliance since 1994.

Click Here for More About Wastewater Management

Advanced Wastewater Treatment

Advanced wastewater treatment is pretty obviously wastewater treatment with one or more advanced aspects.

Integrated has been leading the arena of advanced wastewater treatment for many years with our customized solutions for industries worldwide. We can provide wastewater equipment, chemicals, engineering, design and implementation all in one place.

Read More About Our Advanced Wastewater Treatment

The Myriad Benefits of Floccin™

Industrial Wastewater Treatment Made Easy

This is an introduction to the dry granular Floccin™ product. As you will see, Floccin™ easily encapsulates various contaminates in your wastewater. These contaminates include suspended solids, organics and heavy metals.

Floccin™ operates over a wide pH range, removes more oil, grease and organics than other chemistries, separates the contaminates quickly from the waste stream, requires no additional chemistry to dewater, simplifies the operation by using just one product, and reduces overall operating costs.

Determining The True Costs of Liquid/Solids Separation

Each of these points should be used to clearly define the true operational costs of each wastewater treatment facility and the facility’s potential for cutting costs:

Click Here to Go to the Download Page and Download Your Copy