FRAC Operations Treatability Report Wastewater Treatment Case Study

Impressive Oil Water Separation

Scenario

The water sample from a CUDD Energy oil field site was treated for solids reduction, BOD reduction, metals and dissolved metals.

Metal Machining Wastewater Case Study

The table below shows the results of the analytical, with the untreated water sample and sample treated with Floccin TR-1™. The jar tests below show the effect of the Floccin TR-1™.

Analytical Results

Total Suspended Solids (TSS) 9,300 ppm 160 ppm 98%
Turbidity 180 13 93%
pH 6.77 7.48
Electrical Conductivity 11400 11900 4%
Total Dissolved Solids 9,100 9,000 1%
Metals
Antimony ND ND
Arsenic ND ND
Barium 960 280 71%
Berylium ND ND
Cadmium ND ND
Chromium 13 ND 100%
Cobalt ND ND
Copper ND ND
Iron 8,200 370 95%
Lead ND ND
Manganese 150 130 13%
Mercury 0.26 ND 100%
Molybdenum 48 30 38%
Nickel 16 9.2 43%
Selenium 120 ND 100%
Silver ND ND
Thallium ND ND
Vanadium ND ND
Zinc 32 21 34%
Cations
Calcium 110 120 -9%
Magnesium 11 15 -36%
Potassium 35 37 -6%
Sodium 2,600 2,700 -4%
Anions
Alkalinity (bicarbonate) 750 730 3%
Alkalinity (carbonate) ND ND
Alkalinity (hydroxide) N/A N/A
Boron N/A N/A
Bromide N/A N/A
Chloride 3,500 3,700 -6%
Fluoride N/A N/A
Nitrate ND ND
Sulfate 270 220 19%
Phosphate N/A N/A
Phosphorus N/A N/A

Conclusion

The treatability shows the high removal rate for heavy metals, minimal increase in EC/TDS as shown in the anions/cations and high removal of particulate solids in the form of suspended solids. Increases are shown as negative percent reductions and are the contribution of the Floccin. The minimal increase is less than conventional chemistry. There was not enough sample to test for Total Petroleum hydrocarbons, COD, BOD or any bacterial colony counts.

Click to Download pdf of this FRAC Operations Treatability Report…

Download more industrial wastewater treatment case studies here…

Get Your Own Evaluation…Get Started

Call 1-877-965-1577
Toll Free

Wastewater Treatment Success Stories Home