Tuna Processing & Protein Recovery Wastewater Case Study

Tuna Processing & Protein Recovery Wastewater Case Study – 99% Reduction in TSS – 91% BOD – 7.5% Protein Recovery

The water from a tuna processing facility was treated for solids reduction, BOD reduction and recovery of the protein from the high protein rendering sludge for reuse as animal feed.

The protein is very valuable for use in the animal food industry.

Currently the facility has no process for recovery of the protein and 100% of the high protein rendering sludge is disposed of at the local landfill, costing the company about $200,000 a year in sludge disposable fees without any ROI.

Tortilla Manufacturer Wastewater Case Study

Integrated Engineers, Inc. performed treatability on the water as shown below.  The dosage was quantified to be 4.17lbs of Floccin™ 1105 per 1,000 gallons treated.  The water was then run through analyticals testing which the results are shown below.

Constituent Untreated Treated % Reduction
Total Suspended Solids (TSS) 7,200 ppm 55 ppm 99%
Biochemical Oxygen Demand (BOD) 13,000 ppm 1,100 ppm 91%
Protein Recovery 0 ppm 12,000 ppm 7.5%

Click to Download pdf of this Tuna Processing Wastewater Study…

Download more industrial wastewater treatment case studies here…

Get Your Own Evaluation…Get Started

Call 1-877-965-1577
Toll Free

Wastewater Treatment Success Stories Home