Tuna Processing & Protein Recovery Wastewater Case Study – 99% Reduction in TSS – 91% BOD – 7.5% Protein Recovery
The water from a tuna processing facility was treated for solids reduction, BOD reduction and recovery of the protein from the high protein rendering sludge for reuse as animal feed.
The protein is very valuable for use in the animal food industry.
Currently the facility has no process for recovery of the protein and 100% of the high protein rendering sludge is disposed of at the local landfill, costing the company about $200,000 a year in sludge disposable fees without any ROI.
Integrated Engineers, Inc. performed treatability on the water as shown below. The dosage was quantified to be 4.17lbs of Floccin™ 1105 per 1,000 gallons treated. The water was then run through analyticals testing which the results are shown below.
| Constituent | Untreated | Treated | % Reduction |
|---|---|---|---|
| Total Suspended Solids (TSS) | 7,200 ppm | 55 ppm | 99% |
| Biochemical Oxygen Demand (BOD) | 13,000 ppm | 1,100 ppm | 91% |
| Protein Recovery | 0 ppm | 12,000 ppm | 7.5% |
Click to Download pdf of this Tuna Processing Wastewater Study…
Download more industrial wastewater treatment case studies here…
Call 1-877-965-1577