Oil Water Separation

We’ve added a few new wastewater treatment equipment pages on oil water separation. These links are in the left sidebar of the equipment section as well:

Oil Water Separators

Incoming search terms:

The Myriad Benefits of Floccin™

Industrial Wastewater Treatment Made Easy

This is an introduction to the dry granular Floccin™ product. As you will see, Floccin™ easily encapsulates various contaminates in your wastewater. These contaminates include suspended solids, organics and heavy metals.

Floccin™ operates over a wide pH range, removes more oil, grease and organics than other chemistries, separates the contaminates quickly from the waste stream, requires no additional chemistry to dewater, simplifies the operation by using just one product, and reduces overall operating costs.

Determining The True Costs of Liquid/Solids Separation

Each of these points should be used to clearly define the true operational costs of each wastewater treatment facility and the facility’s potential for cutting costs:

Click Here to Go to the Download Page and Download Your Copy

Incoming search terms:

Floccin™ 909 Wastewater Treatment

100% Wastewater Recycling

55 Gallon Drum & 275 Gallon Tote Washing Operation’s Wastewater Floccin™ 909 Treatability Wastewater Treatment

Floccin™ 909 Wastewater Treatment Creates 100% Wastewater Reuse

This facility receives 55-gallon drums (plastic) and 275 gallon totes (plastic and SS) from several different industries and manufacturer’s including paint, oil field chemicals, acids, caustics, and others.

The RCRA regulated facility cleans the containers and returns them to the customer or grinds them up and recycles the plastic. The facility was using ferric and polymer with some success but recently received their 3rd metals violation for zinc. One more violation and the POTW was going to pull their discharge permit resulting in their shut down.

The sample from this washing operation was at a pH of 6.8 and using Floccin™ 909 quickly separated the solids from the water. The facility is purchasing (3) CFU-50’s for their three facilities and will reuse 100% of their water thereby not discharge water to the local POTW.

55 Gallon Drum Washing Wastewater Treatability Test Before & After Treatment

Click to Download pdf of this 55 Gallon Drum Washing Case Study…

Download more industrial wastewater treatment case studies here…

Get Started…Get Started

Incoming search terms:

Floccin™ 1105 Facilitates 100% Wastewater Reuse

Aggregrate Industry Wastewater Success

Floccin™ 1105 Facilitates Wastewater Reuse

This facility manufactures crushed rock and DOT approved road base for several state highway and airport expansions.

The facility neglected to install a soils entrainment and control plan or system and is in violation of their discharge permit. Integrated Engineers was requested to evaluate the site and make recommendations and a proposed system to mitigate this surface water runoff problem.

The sample from this aggregate operation was jar tested onsite with Floccin™ 1105. With minimal mixing (less than 30 seconds), the solids were agglomerated into a quick settling Floc as shown below.

Part of the proposed 500 gpm system was to utilize this water and reuse 100% of it in their rock washing operations. The dosage was 0.25 grams/1,000 ml.

Aggregate Industry Wastewater Treatability Test Before & After Treatment

Click to Download pdf of this Aggregate Industry Case Study…

Download more industrial wastewater treatment case studies here…

Get Started…Get Started

Incoming search terms: